Product Description

☀️ SOLAR TELECOM RECTIFIER | 4000W | 96% EFFICIENCY

DSD4000-S54F · 4000W Solar Power Supply
For 48V Telecom & Communication Systems

High-efficiency photovoltaic (PV) to DC power module designed for telephone communication base stations, remote shelters, and off-grid telecom sites. Converts 120~440Vdc PV input (MPPT 150~430Vdc) to stable 53.5Vdc / 80A output. Peak efficiency exceeds 96%, supports CAN parallel operation, and operates reliably from -40°C to +75°C.

⚡ 4000W output power
📈 ≥96% peak efficiency
🔄 CAN parallel (current sharing)
❄️ -40°C start-up
🛡️ OVP/OCP/OTP/SCP
🌍 UL60950-1 & EMI Class A

☀️ Key Features & Benefits

⚡ High Efficiency Peak efficiency ≥96% (half load) and ≥95% at full load – reduces energy loss and cooling requirements.
🔌 Wide Input & MPPT Range Input 120~440Vdc, MPPT tracking 150~430Vdc – maximizes solar panel energy harvest even under partial shading or low irradiation.
📡 CAN Parallel Operation Supports up to multiple units in parallel with active current sharing via CAN protocol – ideal for system expansion and redundancy.
❄️ Extreme Temperature Performance Operates from -40°C to +75°C with derating above 45°C. Reliable cold start at -40°C for outdoor installations.
🛡️ Comprehensive Protections Output overvoltage (≥58.5V), overcurrent, short circuit, over temperature, input undervoltage (120±5V), input overvoltage (440±5V).
🔧 Low Ripple & Noise Ripple voltage ≤200mVp-p (20MHz) – clean power for sensitive telecom equipment.
📊 Remote Control & Monitoring CAN communication for remote on/off, voltage/current readback, alarm status, and parallel system management.
🏭 Robust Mechanical Design Metal enclosure, forced air cooling, compact size (281.3×105×40.8mm), weight ≤2.0kg.

🔒 Safety & Compliance

✅ UL60950-1 / UL508 approved
✅ EN55032 Class A (EMI)
✅ IEC61000-4-2, -3, -4, -5, -6, -8, -11
✅ Isolation: Input-PE 2500Vdc, Input-Output 3700Vdc
✅ RoHS & Halogen-free

Meets stringent telecom standards: surge immunity line-to-line 4kV, ESD contact 6kV/air 8kV, burst 4kV. Designed for high-reliability outdoor and indoor telecom cabinets.


#solarrectifier
#telecompower
#PVpowersupply
#48Vrectifier
#CANparallel
#highefficiencypowersupply

📋 Technical Specifications (DSD4000-S54F)

Model No. DSD4000-S54F (V01)
Input Voltage Range 120 ~ 440Vdc (MPPT range 150~430Vdc)
Rated Input Voltage 350Vdc
Max Input Current 21A
Inrush Current ≤30A @250Vdc
Output Voltage Range 42 ~ 58Vdc (typical 53.5Vdc)
Max Output Current 80A
Max Output Power 4000W
Efficiency ≥96% (half load) / ≥95% (full load) @350Vdc
Ripple & Noise ≤200mVp-p (20MHz bandwidth)
Hold-up Time ≥8ms
Line Regulation ≤144mV
Load Regulation ≤144mV
Output Voltage Tolerance ≤0.5%
Output Current Tolerance ≤1%
Temperature Coefficient ≤±0.02%/℃
Input Undervoltage Protection 120±5Vdc (recover 130±5Vdc)
Input Overvoltage Protection 440±5Vdc (recover 390±5Vdc)
Output Overvoltage Protection ≥58.5Vdc
Short Circuit Protection Auto-recovery (hiccup mode)
Over Temperature Protection Yes (auto-recovery)
Communication Interface CAN (support parallel operation & remote monitoring)
Indicators Green (power), Yellow (protection/alarm), Red (HVSD/ESTOP/fan fault)
Operating Temperature -40°C ~ +75°C (derating above 45°C)
Storage Temperature -40°C ~ +85°C
Humidity (Operating/Storage) ≤90% / ≤95% (non-condensing)
Altitude ≤2000m (derating above 2000m)
Cooling Forced air (internal fan)
Isolation Voltage Input-PE: 2500Vdc; Input-Output: 3700Vdc; Output-PE: 707Vdc
Safety Standards UL60950-1, UL508 (24V model), CSA C22.2 No.60950-1
EMC Compliance EN55032 Class A, IEC61000-4-2/3/4/5/6/8/11
Dimensions (W×H×D) 281.3 × 105 × 40.8 mm
Weight ≤2.0 kg
☀️ Optimized for Solar Telecom: Built-in MPPT algorithm (150~430Vdc), wide input range, and high efficiency reduce PV panel requirements. CAN parallel enables easy scaling from 4kW to 40kW+ systems. Front-panel LED status indicators for quick field diagnosis.

🔌 Wiring & Installation Overview

  • PV Input: Terminals 1,2 (PV+), 3,4 (PV-) – accept up to 440Vdc
  • Output: Terminals 13,14 (48V+), 11,12 (48V-) – 80A max
  • Pre-charge: Dedicated pre-charge terminals (11′,12′) for soft start
  • CAN bus: Terminals 7 (CANH), 9 (CANL) for parallel communication
  • PE Ground: Terminals 5,6 for safety earth
  • Parallel up to 10 units with active current balancing
  • Derating: Output power reduces linearly from 100% @45°C to 50% @75°C
  • Altitude derating required above 2000m
  • Forced air cooling – ensure adequate airflow clearance
#PVtotelecom
#solarpowersupply
#48Vpowersystem
#rectifiermodule