Switching Mode Power Supply 4KW Rectifier for Telecom

Product Description

⚡ 4kW RECTIFIER | 97.8% PEAK EFFICIENCY | 75A | CAN PARALLEL | AIR COOLING

DSA4000G-S54F · 4kW High-Efficiency Telecom Rectifier
97.8% Half-Load Efficiency

Next-generation high-density rectifier module engineered for 48V telecom base stations, central offices, and industrial power systems. Delivers 4kW output (75A) with an industry-leading 97.8% efficiency at half load and 95% at full load. Features universal 80-300Vac input, forced air cooling, CAN parallel control, and a compact 1U×2.5U×288mm form factor. Designed for reliable operation from -40°C to +75°C.

⚡ 4kW output power
📈 97.8% efficiency (half load)
🔌 Input 80~300Vac universal
📊 Output 42-58Vdc / 75A
💨 Forced air cooling
📡 CAN parallel control
❄️ -40°C ~ +75°C operation
📏 1U × 2.5U × 288mm

⚡ Unmatched Efficiency & Power Density

🏆 97.8% Peak Efficiency Industry-leading efficiency at half load significantly reduces energy loss and cooling requirements, lowering OPEX in high-uptime installations.
📏 High-Density 1U Form Factor 4kW output in 1U × 2.5U × 288mm – maximizes rack space utilization for high-power telecom shelves and distributed power systems.
🌍 Wide Universal Input 80~300Vac, 45-65Hz – compatible with single-phase and three-phase grids worldwide, tolerant of unstable mains and voltage sags.
🔋 Wide Adjustable Output 42V to 58Vdc (53.5V nominal), 75A continuous current – ideal for 48V LiFePO₄ and lead-acid battery charging as well as direct load supply.
🔄 CAN Parallel Operation Built-in CAN bus enables seamless paralleling of multiple units with active current sharing, supporting N+1 redundancy and system scalability up to 40kW+.
💨 Efficient Air Cooling Forced air cooling with intelligent fan speed control ensures stable full-load operation even at high ambient temperatures, while minimizing audible noise.
🌡️ Wide Operating Temperature -40°C to +75°C (derating above 45°C) – reliable performance in outdoor cabinets, remote shelters, and harsh climate zones.
🛡️ Comprehensive Protections Input over/under voltage, output overvoltage (≥59V), overcurrent, short circuit, over temperature – all with auto-recovery for maximum system uptime.

🔧 Applications & Benefits

📡 4G/5G macro base stations
🏢 Telecom central offices
🔋 Battery backup & charging systems
⚙️ High-density power shelves
🌞 Solar hybrid telecom sites
🔄 N+1 redundant power architecture

The DSA4000G-S54F is the ideal choice for operators seeking to reduce energy costs while increasing power density. Its 97.8% half-load efficiency yields substantial savings over traditional 95% efficient rectifiers. CAN parallel allows intelligent load sharing and remote monitoring via site controllers.


#4kWrectifier
#97.8efficiency
#75Apowersupply
#CANparallel
#telecomrectifier
#highdensitypowersupply

📋 Technical Specifications (DSA4000G-S54F)

Model DSA4000G-S54F
Input Voltage Range 80 ~ 300Vac (single/three-phase compatible)
Input Frequency 45 ~ 65Hz
Output Voltage Range 42 ~ 58Vdc (adjustable, nominal 53.5Vdc)
Max Output Current 75A
Output Power 4000W (4kW)
Efficiency (Half Load) ≥97.8% @ 50% load, nominal input
Efficiency (Full Load) ≥95% @ 100% load, nominal input
Operating Temperature -40°C ~ +75°C (derating above 45°C)
Storage Temperature -40°C ~ +85°C
Cooling Method Forced air cooling (internal fan with speed control)
Ingress Protection IP20 (indoor use)
Communication Interface CAN 2.0 (supports parallel operation, current sharing, remote monitoring)
Parallel Capability Yes, via CAN – up to 10+ units, active current sharing
Dimensions (W × H × D) 1U × 2.5U × 288 mm
(1U ≈ 44.45mm, 2.5U ≈ 111.1mm; depth 288mm)
Weight (approx.) ≤2.0 kg
Input Protections Undervoltage lockout, overvoltage shutdown (auto-recovery)
Output Protections Overvoltage (≥59Vdc), overcurrent, short circuit (hiccup)
Temperature Protection Over temperature shutdown with auto-recovery
MTBF >200,000 hours @ 25°C (Telcordia SR-332)
Compliance RoHS, UL60950-1 (reference), EN55022 Class A, IEC61000-4 series
97.8% efficiency advantage: Compared to a 95% efficient unit, the DSA4000G-S54F saves over 115W of heat dissipation per module at half load – reducing cooling costs and improving system reliability.

📐 Integration & Derating Information

  • Form factor: 1U height × 2.5U width – fits standard 19″ telecom subracks and power shelves.
  • Connectors: Rear plug-in type (AC input, DC output, CAN, signal) – hot-swap compatible.
  • Cooling clearance: Allow 30mm minimum airflow clearance at intake and exhaust.
  • Derating curve: 100% output up to 45°C, linearly derating to 50% output at 75°C.
  • Altitude derating: Required above 2000m – consult factory for derating factors.
  • Status indicators: Front-panel LEDs for input OK, output OK, alarm/communication status.
#hotswap
#1Urectifier
#telecomshelf
#highcurrent