Switching Mode Power Supply 6KW Rectifier for Telecom AAU

Product Description

 

🏢 INDOOR TELECOM RECTIFIER | 6kW | WIDE INPUT | NATURAL COOLING | CAN 2.0

DSA6000-S54F · 6kW Indoor Rectifier Module
40-120Vdc Adjustable Output

High-efficiency, wide-input rectifier module designed for indoor telecom central offices, base stations, and industrial DC power systems. Converts 205~456Vac AC mains to a programmable 40~120Vdc output (66.7A max) with 95% efficiency. Features natural convection cooling, IP20 rating, CAN 2.0 communication, and reliable -40°C to +75°C operation.

⚡ 6kW output power
🔌 Wide input 205~456Vac
📊 Output 40-120Vdc / 66.7A
📈 95% efficiency (full load)
💨 Natural air cooling (fanless)
🛡️ IP20 indoor rating
📡 CAN 2.0 communication
❄️ -40°C ~ +75°C operation

⚡ High-Performance Indoor Rectifier

🌍 Ultra-Wide Input Range 205~456Vac (single/three-phase compatible) – supports global power grids with high tolerance to voltage fluctuations.
🔋 Wide Adjustable Output 40V to 120Vdc continuous adjustment – covers 48V, 60V, 72V, 96V, and 110V telecom and industrial DC bus standards.
📈 High Efficiency 95% efficiency at full load reduces energy consumption and heat dissipation, lowering OPEX in high-density installations.
💨 Natural Convection Cooling Fanless design eliminates acoustic noise and moving parts – ideal for office environments and noise-sensitive indoor sites.
📡 CAN 2.0 Communication Standard CAN 2.0 interface enables remote monitoring, parallel operation, current sharing, and system integration with central controllers.
🌡️ Wide Operating Temperature -40°C to +75°C (derating above 55°C) – reliable performance in unconditioned indoor spaces or harsh temperature environments.
🏭 Compact & Lightweight Dimensions 386.1×176.4×85mm, weight ≤6kg – high power density for space-constrained 19″ racks and telecom shelves.
🛡️ Comprehensive Protections Overvoltage, overcurrent, short circuit, over temperature, and input undervoltage/overvoltage protection – auto-recovery ensures system uptime.

🔧 Applications & Advantages

📡 Telecom central offices (CO)
🏭 Industrial DC power systems
🔋 Battery charging & conditioning
📡 4G/5G base stations
⚙️ DC UPS systems
🏢 Data center power distribution

The DSA6000-S54F is ideal for indoor telecom applications where silent operation, wide voltage range, and high reliability are required. Natural cooling eliminates fan maintenance, and the wide output range supports multiple voltage standards in one module.


#indoorrectifier
#telecomrectifier
#6kWpowersupply
#40-120Vdc
#naturalcooling
#CAN2.0
#fanlessrectifier

📋 Technical Specifications (DSA6000-S54F)

Model DSA6000-S54F
Input Voltage Range 205 ~ 456Vac (single/three-phase)
Rated Input Voltage 380Vac (typical)
Input Frequency 45 ~ 65Hz
Output Voltage Range 40 ~ 120Vdc (adjustable)
Rated Output Voltage 54Vdc / 48V / 60V / 72V / 96V / 110V (programmable)
Max Output Current 66.7A (at 90Vdc, 6kW)
Output Power 6000W (constant power)
Efficiency (Full Load) ≥95%
Efficiency (Typical) 95% @ 380Vac input, full load
Operating Temperature -40°C ~ +75°C (derating above 55°C)
Storage Temperature -40°C ~ +85°C
Cooling Method Natural air cooling (fanless)
Ingress Protection IP20 (indoor use)
Communication Interface CAN 2.0 (supports parallel operation & remote monitoring)
Dimensions (L × W × H) 386.1 × 176.4 × 85 mm
Weight ≤6.0 kg
Input Protection Undervoltage, overvoltage (auto-recovery)
Output Protection Overvoltage, overcurrent, short circuit
Temperature Protection Over temperature shutdown with auto-recovery
Parallel Capability Yes, via CAN 2.0 with active current sharing
Compliance RoHS, UL60950-1 (reference), EMI Class A
CAN 2.0 & Parallel Operation: The DSA6000-S54F supports up to 10+ units in parallel with automatic current sharing via CAN bus, enabling N+1 redundancy and scalable power up to 60kW+ for large telecom halls.

📐 Installation & Integration Notes

  • Mounting: Standard 19″ rack or shelf mount – fits 2U/3U form factor (height 85mm ≈ 2U).
  • Cooling clearance: Natural convection requires adequate ventilation; maintain 50mm clearance on intake/exhaust sides.
  • Input wiring: 3-phase or single-phase compatible; refer to manual for terminal assignment.
  • Derating curve: 100% output up to 55°C, linearly derating to 50% at 75°C.
  • Output adjustment: Voltage setpoint adjustable via CAN commands or local potentiometer (if equipped).
  • Status indicators: Front-panel LEDs for power, alarm, and communication status.
#19inchrectifier
#rackmount
#telecomshelf
#highdensity