Switching Mode Power Supply 3KW Rectifier for Telecom

Product Description

🏭 MACRO BASE STATION | 1U EMBEDDED MODULE | 3kW | NATURAL COOLING

DSA3000-S54E Β· 3kW 1U Embedded Rectifier
For 48V Telecom Systems

Ultra-compact, high-density rectifier module specifically designed for macro base stations and telecom central offices. Delivers 3kW of regulated DC power in a slim 1U form factor (287Γ—105Γ—40.8mm). Features wide universal input (80-300Vac), 42-58Vdc adjustable output (62.5A max), 96% efficiency, natural convection cooling, and CAN 2.0 communication. Ideal for embedded power shelves and distributed 48V architectures.

⚑ 3kW output power
πŸ“ 1U slim profile (40.8mm)
πŸ”Œ Input 80~300Vac universal
πŸ“Š Output 42-58Vdc / 62.5A
πŸ“ˆ 96% efficiency (full load)
πŸ’¨ Natural air cooling (fanless)
πŸ“‘ CAN 2.0 communication
❄️ -40Β°C ~ +75Β°C operation
βš–οΈ 1.75kg lightweight

πŸ“‘ Optimized for Macro Base Stations

πŸ“ 1U Ultra-Slim Design Height only 40.8mm – fits standard 19″ telecom shelves and embedded cabinets. High power density (3kW per module) maximizes rack utilization.
🌍 Universal Wide Input 80~300Vac – works with single-phase or three-phase mains worldwide, tolerating wide voltage fluctuations and unstable grids.
πŸ”‹ Wide Output Range 42V to 58Vdc adjustable (62.5A max) – perfect for 48V lithium or lead-acid battery charging and direct load powering.
πŸ“ˆ High Efficiency (96%) 96% efficiency at full load reduces heat generation and energy costs. Lower thermal stress improves long-term reliability.
πŸ’¨ Natural Convection Cooling Fanless operation eliminates acoustic noise and moving parts – ideal for noise-sensitive indoor environments and low-maintenance deployments.
πŸ“‘ CAN 2.0 Communication Standard CAN 2.0 interface enables remote monitoring, parallel current sharing, N+1 redundancy, and seamless integration with site controllers.
🌑️ Extreme Temperature Range -40Β°C to +75Β°C operation (derating above 55Β°C) – reliable for outdoor shelters, remote huts, and harsh climate regions.
πŸ›‘οΈ Comprehensive Protections Input over/under voltage, output overvoltage (β‰₯59V), overcurrent, short circuit, and over temperature protection – auto-recovery ensures maximum uptime.

πŸ”§ Applications & System Integration

πŸ“‘ Macro base stations (4G/5G)
🏭 Telecom central offices
πŸ”‹ Battery backup systems
βš™οΈ Distributed power shelves
🏒 Indoor DC power distribution
πŸ”„ N+1 redundant power systems

The DSA3000-S54E is the ideal building block for high-density telecom power systems. Up to 12 modules can be paralleled via CAN bus to achieve 36kW+ with active current sharing. Hot-swappable design (where supported by shelf) simplifies maintenance.


#macroBaseStation
#1Urectifier
#3kWtelecom
#embeddedpowersupply
#naturalcooling
#CAN2.0

πŸ“‹ Technical Specifications (DSA3000-S54E)

Model DSA3000-S54E
Input Voltage Range 80 ~ 300Vac (single/three-phase compatible)
Input Frequency 45 ~ 65Hz
Output Voltage Range 42 ~ 58Vdc (adjustable, default 53.5Vdc)
Max Output Current 62.5A
Output Power 3000W (3kW)
Efficiency (Full Load) β‰₯96% @ nominal input
Operating Temperature -40Β°C ~ +75Β°C (derating above 55Β°C)
Storage Temperature -40Β°C ~ +85Β°C
Cooling Method Natural air convection (fanless)
Ingress Protection IP20 (indoor use)
Communication Interface CAN 2.0 (supports parallel operation, current sharing, remote monitoring)
Dimensions (W Γ— H Γ— D) 287 Γ— 105 Γ— 40.8 mm (1U height)
Weight ≀1.75 kg
Input Protections Undervoltage lockout, overvoltage shutdown (auto-recovery)
Output Protections Overvoltage (β‰₯59Vdc), overcurrent, short circuit (hiccup mode)
Temperature Protection Over temperature shutdown with auto-recovery
Parallel Capability Yes, via CAN 2.0 – up to 12+ units, current sharing accuracy ≀5%
MTBF >200,000 hours @ 25Β°C (Telcordia SR-332)
Compliance RoHS, UL60950-1 (reference), EN55022 Class A, IEC61000-4 series
High-density 1U architecture: The DSA3000-S54E packs 3kW into a 40.8mm height module. Its natural cooling design eliminates fan noise and maintenance, while CAN 2.0 enables intelligent system integration. Perfect for macro base station retrofits and new high-efficiency power shelves.

πŸ“ Mechanical & Integration Details

  • Form factor: 1U height (40.8mm) Γ— 105mm width Γ— 287mm depth – fits standard 19″ subracks and embedded shelves.
  • Connectors: Rear plug-in type (AC input, DC output, CAN, and signal pins) – hot-swap ready.
  • Mounting: Horizontal insertion into a dedicated power shelf (requires mating backplane).
  • Derating curve: 100% output up to 55Β°C ambient, linearly derating to 50% output at 75Β°C.
  • Altitude derating: Required above 2000m (consult factory).
  • Status LEDs: Front panel indicators for AC OK, DC OK, and alarm/fault.
#hotswap
#1Urectifier
#telecomshelf
#embeddedpower